Project Description

HEC Commercial Circulator Pump

Electronically controlled and high efficiency circulator pumps for commercial buildings.

Suitable for:

  • Commercial air conditioning
  • Commercial heating
  • Commercial hot water recirculation
  • District cooling
  • District heating
  • Domestic hot water recirculation
  • Domestic heating
  • Cooling
  • Industrial heating

Supply voltage:
Flow rate, Qmax:
Pump head, Hmax:
Liquid temperature:
System pressure, Pmax:
Power Range:
Ambient temperature:
EEI:
Enclosure class:
Insulation class:
1 x 230 V – 50/60 Hz
10.8 m3/h
10 m
+2°C to +110°C (TF 110)
1.0 MPa/10 bar
5-47 W
0°C to +40°C
≤ 0.23
IP 44
F

» Ready for Conversion according to Ecodesign Requirements for 2015(ErP) with EEI ≤ 0.23
» Providing energy savings and comfort level
» Automatic and continuous detection of optimal duty point by ECO
» High safety – built-in electrical and thermal protection of the pump
» Fault prompt function
» Low noise level
» Based on 500,000 times test in extreme conditions » Suitable for light commercial application

Get A Quote Now

Key Features

Constant speed mode

Two constant speed modes – min. and max. -for constant flow applications

 

Constant pressure mode

• The pump maintains constant pressure regardless of the flow
• The preferred operation mode for under floor heating and 2 string systems with low flow variation

Proportional pressure mode

• If the proportional pressure mode is selected, the differential pressure varies proportionally with the flow, i.e. higher flow means higher differential pressure
• Proportional pressure is the preferred choice for one-string systems with high flow variation

ECO mode

• The factory setting, ECO, analyzes the heating system and automatically adjusts the pump setting to meet the heating requirement. The result is optimum comfort and a minimum of energy consumption.
• ECO can be used in 80% of the heating system.

Air-vent mode

Press the setting button  for 6 seconds under this mode to vent air in the pump.

Technical Data

Type Max. volume flow
Qmax
Max. delivery head
Hmax
Energy efficiency
index (EEI)
Thread Threaded pipe
union
Rated
pressure
Overall
length
Mains
connection
Gross
weight
HEC 25/8 7.5 m³/h 8 m ≤ 0.23 G 1 1/2″ G 1″ 10 bar 180 mm 1~230 V,
50/60 Hz
3.5 kg
HEC 25/10 7.8 m³/h 10 m ≤ 0.23 G 1 1/2″ G 1″ 10 bar 180 mm 1~230 V,
50/60 Hz
3.5 kg
HEC 32/8 10.2 m³/h 8 m ≤ 0.23 G 2″ G 1 1/4″ 10 bar 180 mm 1~230 V,
50/60 Hz
3.7 kg
HEC 32/10 10.8 m³/h 10 m ≤ 0.23 G 2″ G 1 1/4″ 10 bar 180 mm 1~230 V,
50/60 Hz
3.7 kg

Measurement

                                                           

Type L1
(mm)
L2
(mm)
B1
(mm)
B2
(mm)
H1
(mm)
H2
(mm)
G
(inch)
Material of rear housing
HEC 25/x 180 90 129 64.5 236 184 1 1/2″ cast iron
HEC 32/x 180 90 129 64.5 236 184 2″ cast iron