HEC-G Commercial Circulator Pump
Electronically controlled and high efficiency circulator pumps for commercial buildings.
Suitable for:
- Commercial air conditioning
- Commercial heating
- Commercial hot water recirculation
- District cooling
- District heating
- Domestic hot water recirculation
- Domestic heating
- Cooling
- Industrial heating
Supply voltage:
Flow rate, Qmax:
Pump head, Hmax:
Liquid temperature:
System pressure, Pmax:
Power Range:
Ambient temperature:
EEI:
Enclosure class:
Insulation class:1 x 230 V – 50/60 Hz
10.8 m3/h
10 m
+2°C to +110°C (TF 110)
1.0 MPa/10 bar
5-47 W
0°C to +40°C
≤ 0.23
IP 44
F
» Ready for Conversion according to Ecodesign Requirements for 2015(ErP) with EEI ≤ 0.23
» Providing energy savings and comfort level
» Automatic and continuous detection of optimal duty point by ECO
» High safety – built-in electrical and thermal protection of the pump
» Fault prompt function
» Low noise level
» Based on 500,000 times test in extreme conditions » Suitable for light commercial application
Key Features
Constant speed mode
Two constant speed modes – min. and max. -for constant flow applications
Constant pressure mode
• The pump maintains constant pressure regardless of the flow
• The preferred operation mode for under floor heating and 2 string systems with low flow variation
Proportional pressure mode
• If the proportional pressure mode is selected, the differential pressure varies proportionally with the flow, i.e. higher flow means higher differential pressure
• Proportional pressure is the preferred choice for one-string systems with high flow variation
ECO mode
• The factory setting, ECO, analyzes the heating system and automatically adjusts the pump setting to meet the heating requirement. The result is optimum comfort and a minimum of energy consumption.
• ECO can be used in 80% of the heating system.
Technical Data
Type | Max. volume flow Qmax | Max. delivery head Hmax | Energy efficiency index (EEI) | Thread | Threaded pipe union | Rated pressure | Overall length | Mains connection |
---|---|---|---|---|---|---|---|---|
HEC-G 25/10 | 8.5 m³/h | 10 m | ≤ 0.23 | G 1 1/2″ | G 1″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |
HEC-G 25/12 | 9.2 m³/h | 12 m | ≤ 0.23 | G 1 1/2″ | G 1″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |
HEC-G 25/15 | 10 m³/h | 15 m | ≤ 0.23 | G 1 1/2″ | G 1″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |
HEC-G 25/18 | 10.5 m³/h | 18 m | ≤ 0.23 | G 1 1/2″ | G 1″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |
HEC-G 32/10 | 8.5 m³/h | 10 m | ≤ 0.23 | G 2″ | G 1 1/4″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |
HEC-G 32/12 | 9.2 m³/h | 12 m | ≤ 0.23 | G 2″ | G 1 1/4″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |
HEC-G 32/15 | 10 m³/h | 15 m | ≤ 0.23 | G 2″ | G 1 1/4″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |
HEC-G 32/18 | 10.5 m³/h | 18 m | ≤ 0.23 | G 2″ | G 1 1/4″ | 10 bar | 180 mm | 1~230 V, 50/60 Hz |